Model # |
Name |
Description |
 |
FR882B |
3-Lead Isolated Cable ECG Kit for iWorx recorders |
This cuvette is used for performing blood volume calibrations for rodent studies. The cuvette has 10 wells divided in to two ranges, 10-50 uL for mouse studies and 200-600 uL for rat. Total volume is determined by the radius of the well and the electrode spacing of our standard mouse and rat catheters (where L is 4.5 mm and 8.0 mm, respectively). Note, if other electrode spacings are used then overall well volumes are effected (ie. Vol = p(r)^2*L) |
 |
FR382B |
Calibration Cuvette (VSL Rat & Rabbit) |
This cuvette is used for performing blood volume calibrations for rat or rabbit studies. The cuvette has 12 wells, increasing in diameter from 6 mm to 18 mm . Total volume is determined by the radius of the well and the electrode spacing of the catheter (ie. Vol = p(r)^2*L). |
 |
FR982B |
Calibration Cuvette (Large Animal) |
This cuvette is used for performing blood volume calibrations for large animal studies. The cuvette has 10 wells, increasing in diameter from 9.6 mm to 38.2 mm . Total volume is determined by the radius of the well and the sum of the segmental electrode sections that are active on the catheter (ie. Segmental Vol. = p(r)^2*L, where L is the segmental length).
|
| --- Image coming soon --- |
AMB-2053 |
Conductivity Meter (includes dip cell and cell cup)
|
The Amber Sciences digital conductivity meter features three modes of operation: one for self check; and two for measuring conductivity (from 20 micro Siemens to 20 milli-Siemens). The conductivity measurement readings are displayed on a 3½ digit LCD with a floating decimal. The Self Check feature provides verification of proper operation, and the ability to adjust for cell constant variations. The instrument also has automatic temperature compensation (ATC) for slope correction. |
| --- Image coming soon --- |
650-950
|
Delta-Cal Pressure Transducer Stimulator/Tester |
A very valuable tool to accompany pressure and pressure-volume systems: the Delta-CalT hand-held calibration device provides verification of system accuracy by producing a known pressure value to eliminate use of mercury monometers. It features an easy to read LCD display for comparison to monitor readings, measures full range of pressure: -300 to +300 mmHg, and operates on a standard 9 volt battery |
| --- Image coming soon --- |
WPI-ABM |
WPI Audible Baseline Monitor
|
A unique device for integration into a rodent surgical platform. The baseline monitor is connected to your LV pressure channel and programmed to notify the surgeon when the catheter has advanced through the aortic valve from the aorta into the LV
|
| --- Image coming soon --- |
FC-IX-ISO-104
|
3-Lead Isolated Cable ECG Kit for iWorx recorders
|
An external 3-lead ECG kit for rodent applications. Kit connects to iWorx recorders and amplifiers |
 |
FC-IX-ISO-255
|
3-Lead Isolated Wide Bandwidth Cable ECG Kit iWorx recorders
|
An external 3-lead ECG kit for large animal applications. Kit connects to iWorx recorders and amplifiers
|
 |
IX-BP-100
|
Blood Pressure Transducer (Fluid-Filled)
|
Dome style external pressure transducer available as an alternative to Scisense solid state catheters. Suitable for large animal blood pressure use ONLY.
|
| --- Image coming soon --- |
FS-AULT301
|
AULT Power Supply
|
Internationally compliant power supply for the following Scisense equipment: FP891B, FP895B, FV896B, FV898B, and other miscellaneous items.
|
| --- Image coming soon --- |
FS-PCM50UT04
|
XP Power Supply
|
Internationally compliant power supply for the following Scisense equipment: FP992B.
|