This page makes use of style sheets to control page presentation, in compliance with the World Wide Web consortium's standards. If you are seeing this message, the style sheets are not available either because of an error or because you are using a browser that is not standards-compliant (possibly Netscape 4). The information on this Web site will still be accessible to you.

Scisense Inc. Logo
Pressure-Volume Catheters - Large Animal

7F PV Catheter (pigtail) - Click to view full image

Pressure-Volume Catheters

Class: Medium Animal / Rabbit

Model # Name Description

FTS-3512B-5024

3.5F Pressure-Volume Catheter

The ideal multi-segment PV catheter for rabbit ventricular pressure-volume data collection. Three volume segments are available, spaced at 4.0 mm standard for a Rabbit LV application: custom segment lengths are available free of charge

Class: Large Animals (dog, pig, sheep)

Model # Name Description

FTS-5012B-7048B

5.0F Pressure-Volume Catheter with a Pigtail Tip

A 5.0F multi-segment Pressure-Volume catheter designed specifically for closed chest protocols where a carotid or femoral artery insertion will be used. Standard volume electrode spacing is 7.0mm, which can be altered free of charge.

FTS-5012B-7048D

5.0F Pressure-Volume Catheter with a Straight Tip

A 5.0F multi-segment Pressure-Volume catheter ideal for left ventricular PV studies where an open chest surgery and apical insertion is used. Standard volume electrode spacing is 7.0mm, which can be altered free of charge.

FTS-7012B-7048A

7.0F Pressure-Volume Catheter with a Pigtail Tip and Lumen

A 7.0F multi-segment Pressure-Volume catheter designed specifically for closed chest protocols where a carotid or femoral artery insertion will be used. A central catheter lumen is accessible for drug administration, blood sampling, or guidewire insertion. Standard volume electrode spacing is 7.0mm, which can be altered free of charge.

FTS-7012B-7048B

7.0F Pressure-Volume Catheter with a Closed Pigtail Tip

A 7.0F multi-segment Pressure-Volume catheter designed specifically for closed chest protocols where a carotid or femoral artery insertion will be used. Standard volume electrode spacing is 7.0mm, which can be altered free of charge.

FTS-7012B-7048C

7.0F Pressure-Volume Catheter with a Straight Tip and Lumen

A 7.0F multi-segment Pressure-Volume catheter ideal for left ventricular PV studies where an open chest surgery and apical insertion is used. A central catheter lumen is accessible for drug administration and blood sampling. Standard volume electrode spacing is 7.0mm, which can be altered free of charge.

FTS-7012B-7048D

7.0F Pressure-Volume Catheter with a Straight Tip

A 7.0F multi-segment Pressure-Volume catheter ideal for left ventricular PV studies where an open chest surgery and apical insertion is used. Standard volume electrode spacing is 7.0mm, which can be altered free of charge.

Top

Dual Pressure-Volume Catheters

Class: Medium Animal / Rabbit

Model # Name Description

FTS-3514B-4024-2

3.5F Dual Pressure-Volume Catheter with a Straight Tip

A specialty 3.0F Dual Pressure-Volume catheter: the first pressure sensor is located between E3 and E4 for ventricular pressure detection, while the second is proximal by 2 cm from E6. This particular spacing is best for combination left ventricular pressure and carotid blood pressure in the rabbit model. Note that the distance between the two sensors can be adjusted as required at no extra cost.

Class: Large Animals (dog, pig, sheep)

Model # Name Description

FTS-5014B-7048B-5

5.0F Dual Pressure-Volume Catheter with a Pigtail Tip

A specialty 5.0F Dual Pressure-Volume catheter to be used in carotid or femoral artery insertions into the ventricle: the first sensor is located between E3 and E4, while the second is proximal by 5 cm from E8. Note that the distance between the two sensors can be adjusted as required at no extra cost.

FTS-5014B-7048D-5

5.0F Dual Pressure-Volume Catheter with a Straight Tip

A specialty 5.0F Dual Pressure-Volume catheter to be used for open chest surgery where an apical insertion is used. The carotid blood pressure sensor is located slightly proximal of the catheter tip, while the second is positioned between E3 and E4. Note that E1 begins 6 cm from the catheter tip. The distance between the two sensors can be adjusted as required at no extra cost.

FTS-7014B-7048A-5

7.0F Dual Pressure-Volume Catheter with a Pigtail Tip and Lumen

A specialty 7.0F Dual Pressure-Volume catheter to be used in carotid or femoral artery insertions into the ventricle: the first sensor is located between E3 and E4, while the second is proximal by 5 cm from E8. Note that the distance between the two sensors can be adjusted as required at no extra cost. A central catheter lumen is accessible for drug administration, blood sampling, or guidewire insertion

FTS-7014B-7048B-5

7.0F Dual Pressure-Volume Catheter with a Closed Pigtail Tip

A specialty 7.0F Dual Pressure-Volume catheter to be used in carotid or femoral artery insertions into the ventricle: the first sensor is located between E3 and E4, while the second is proximal by 5 cm from E8. Note that the distance between the two sensors can be adjusted as required at no extra cost.

FTS-7014B-7048C-5

7.0F Dual Pressure-Volume Catheter with a Straight Tip and Lumen

A specialty 7.0F Dual Pressure-Volume catheter to be used for open chest surgery where an apical insertion is used. The carotid blood pressure sensor is located slightly proximal of the catheter tip, while the second is positioned between E3 and E4. Note that E1 begins 6 cm from the catheter tip. The distance between the two sensors can be adjusted as required at no extra cost. A central Dual Pressure-Volume catheter lumen is accessible for drug administration and blood sampling.

FTS-7014B-7048D-5

7.0F Dual Pressure-Volume Catheter with a Straight Tip

A specialty 7.0F Dual Pressure-Volume catheter to be used for open chest surgery where an apical insertion is used. The carotid blood pressure sensor is located slightly proximal of the catheter tip, while the second is positioned between E3 and E4. Note that E1 begins 6 cm from the catheter tip. The distance between the two sensors can be adjusted as required at no extra cost.