Pressure and pressure volume systems for measuring blood pressure, volume, pv loops, and ECG. Pressure Volume Equipment Hardware, ADVantage, Pressure Measurement
|
|
![]() |
![]() |
Class: Large Animals
| Name | Description | Recommended Long Axis Length | Minimum Long Axis Length |
|---|---|---|---|
5.0F VSL Pressure-Volume Catheter with a Straight Tip and No Lumen |
A 5.0F Pressure-Volume catheter that offers four different volume electrode spacings: 20mm, 30mm, 40mm, and 50mm. This is the ideal PV catheter for studies whtere there is an expectation that the ventricular long axis length space may increase or decrease, thus still supporting "best fit" for the volume electrodes. |
30.0 mm to |
30.0 mm |
5.0F VSL Pressure-Volume Catheter with a Pigtail Tip and No Lumen |
A 5.0F Pressure-Volume catheter that offers four different volume electrode spacings: 20mm, 30mm, 40mm, and 50mm. This is the ideal PV catheter for studies whtere there is an expectation that the ventricular long axis length space may increase or decrease, thus still supporting "best fit" for the volume electrodes. |
47.0 mm to |
47.0 mm |
7.0F VSL Pressure-Volume Catheter with a Straight Tip and No Lumen |
A 7.0F Pressure-Volume catheter that offers four different volume electrode spacings: 30mm, 40mm, 50mm, and 60mm. This is the ideal PV catheter for studies whtere there is an expectation that the ventricular long axis length space may increase or decrease, thus still supporting "best fit" for the volume electrodes. |
50.0 mm to |
50.0 mm |
7.0F VSL Pressure-Volume Catheter with a Straight Tip and Lumen |
A 7.0F Pressure-Volume catheter that offers four different volume electrode spacings: 30mm, 40mm, 50mm, and 60mm. This is the ideal PV catheter for studies whtere there is an expectation that the ventricular long axis length space may increase or decrease, thus still supporting "best fit" for the volume electrodes. |
50.0 mm to |
50.0 mm |
7.0F VSL Pressure-Volume Catheter with a Pigtail Tip and Lumen |
A 7.0F Pressure-Volume catheter that offers four different volume electrode spacings: 30mm, 40mm, 50mm, and 60mm. This is the ideal PV catheter for studies whtere there is an expectation that the ventricular long axis length space may increase or decrease, thus still supporting "best fit" for the volume electrodes. |
57.0 mm to |
57.0 mm |
7.0F VSL Pressure-Volume Catheter with a Pigtail Tip and No Lumen |
A 7.0F Pressure-Volume catheter that offers four different volume electrode spacings: 30mm, 40mm, 50mm, and 60mm. This is the ideal PV catheter for studies whtere there is an expectation that the ventricular long axis length space may increase or decrease, thus still supporting "best fit" for the volume electrodes. |
57.0 mm to |
57.0 mm |
Small Animal Admittance Catheters | Back to the Products Page