This page makes use of style sheets to control page presentation, in compliance with the World Wide Web consortium's standards. If you are seeing this message, the style sheets are not available either because of an error or because you are using a browser that is not standards-compliant (possibly Netscape 4). The information on this Web site will still be accessible to you.

Scisense Inc. Logo
VSL Pressure-Volumne Control Units

VSL Pressure-Volume Control Unit - FV898B
FV898B

The Scisense FV898B VSL Pressure-Volume control unit is a dual-input signal conditioner and amplifier for in vitro ‘Working Heart’ applications and for operation of our unique VSL (Variable Segment Length) pressure-volume sensors. The FV898B control unit is equipped with both Gain and Offset controls allowing researchers to calibrate to unique buffer solutions, such as Krebs-Heiselate. Secondly, Scisense VSL pressure-volume catheters are valuable in that they provide 4 different electrode spacings for conductance volume recordings. Researchers can therefore select the spacing that ‘best fits’ the heart they are studying, ensuring the utmost accurate measurements. The system ultimately provides a comprehensive analysis of hemodynamics and indices of cardiac contractility for both in vivo and in vitro protocols. The control unit is equipped with a 2-point electronic calibration for pressure with zero balance control. The FV898B control unit can be connected to any data acquisition system via two BNC terminals.

Applications:

Specific to VSL Control Unit and VSL Catheters

  • Isolated mouse, rat, and rabbit
  • Working Heart studies
  • cardiac hypertrophy and distension
  • diabetes mellitus
  • all mid-size animal PV research (ie. Rabbit)
  • All standard Pressure-Volume studies apply as well; for a list of common studies see the "Applications" section of the Scisense Rodent Pressure- Volume System - FV896B
Specifications:

Number of Inputs: 2: 1 standard (9 pin Redel), 1 VSL (14 pin Redel)
Pressure Output: 2.3 Volt/100 mmHg
Power Supply Out: +5VDC, +/- 12 VDC
Power Supply In: 100-250 Vac, 50-60 Hz
Dimensions: H : 6.9 cm (2.7”)
W : 22.6 cm (8.9")
L : 16.8 cm (6.6")
Calibration Controls: Pressure: 0 mmHg (-2.86V) and 100 mmHg (-0.57V)
Conductance:
Fully Adjustable using Gain and Offset Controls
Range = Approximately +/- 8V
Catheter Cable: 122 cm (48”) cable (for standard and VSL)
Output Connector: BNC
Signal Gain: 1143 (Pressure)

Ordering Information:

The Scisense Pressure-Volume Control Unit FV898B requires the following items:

  • Cable package FC-VSL-PK, which includes: AULT Power Supply (FS-AULT301), Power Cord, (1) Scisense Catheter Cable (FC-1394-4), Scisense VSL Catheter Cable (FC-VSL-4), and (2) BNCBNC Cable (FC-BNC-6)
  • VSL Calibration Cuvette( FR382B), for raw blood sample and Buffer calibrations

The Scisense Pressure-Volume Control Unit FV898B can be paired with a data acquisition and analysis package to create a turn-key solution. Options supported by and available from Scisense are:

  • Ponemah Life Sciences Suite Eight or Sixteen Channel Data Acquisition and Analysis Platform including Pressure-Volume Analysis Module
  • Scisense FA-404 Four Channel Data Acquisition Box with LabScribe2 Software including Pressure- Volume Analysis
  • Custom Packages can be created with additional input channels and analysis modules to best suit your research needs; please contact Scisense and a representative would be happy to assist you.